{"id":7596,"date":"2021-10-02T07:14:50","date_gmt":"2021-10-02T07:14:50","guid":{"rendered":"https:\/\/sayprotest.com\/dogru-alcak-gerilim-parafudru-secimi-nasil-yapilir\/"},"modified":"2021-10-12T05:05:04","modified_gmt":"2021-10-12T05:05:04","slug":"how-to-choose-the-right-low-voltage-surge-arrester","status":"publish","type":"post","link":"https:\/\/www.saypro.com.tr\/en\/how-to-choose-the-right-low-voltage-surge-arrester\/","title":{"rendered":"How to Choose the Right Low Voltage Surge Arrester?"},"content":{"rendered":"<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">The selection of the low voltage surge arresters we use in lightning and overvoltage protection is of great importance in correct protection. The wrong product selection unfortunately results in the breakdown of sensitive devices in many facilities. In order to choose the right product, let&#8217;s first look at the types of surge arresters.<\/span><\/span><\/p>\n<h4><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">AG Surge Arrester Classes<\/span><\/span><\/strong><\/h4>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">AG Surge Arresters are basically 3 types. Network surge arresters, which we call Type 1 or Class B, are used for lightning protection. This type of products should be used in main boards. Network surge arresters called Type 2 or Class C are used in secondary panels. Finally, Type 3 D class network surge arresters are used for the protection of endpoint sensitive systems (camera, UPS, data, etc.).<\/span><\/span><\/p>\n<h4><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">AG Surge Arrester Parameters<\/span><\/span><\/h4>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">Another important factor for us to choose the right surge arrester is to know what the parameters of the surge arrester mean. Now let&#8217;s look at what these parafurd parameters mean.<\/span><\/span><\/p>\n<p><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">-Uc Operating Voltage<\/span><\/span><\/strong><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">Uc operating voltage is the maximum operating voltage that can be applied to the surge arrester continuously. Values \u200b\u200bare 220 V, 12 V, 400 v etc.<\/span><\/span><\/p>\n<p><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">2-Ut Transient Overvoltage<\/span><\/span><\/strong><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">Ut transient overvoltage is the maximum voltage that the surge arrester can withstand for 5 seconds without being damaged. It is important that the surge arrester is not affected by the network voltages that change from time to time.<\/span><\/span><\/p>\n<p><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">3-Discharge Current (In and Imax)<\/span><\/span><\/strong><\/p>\n<ul>\n<li><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">The maximum discharge current is the maximum current that Imax Type 2 surge arresters can withstand without being damaged in the 8\/20 microsecond curve.<\/span><\/span><\/li>\n<li><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">The rated discharge current is the impulse current that In Ti 1 and Type 2 surge arresters can carry without being damaged. It can withstand 15 consecutive blows.<\/span><\/span><\/li>\n<\/ul>\n<p><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">4-Pulse Current Iimp<\/span><\/span><\/strong><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">The impulse current is the current that Type 1 surge arresters can withstand without being damaged in impulses (lightning strikes) in the 10\/350 microsecond curve.<\/span><\/span><\/p>\n<p><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">5-Up Protection Level<\/span><\/span><\/strong><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">It is the voltage value that the Up Surge Arrester carries on when it carries the nominal discharge current to the ground, which is called the maximum protection voltage. The lower this value, the better the protection. According to the IEC 60364 standard, 2.5 kV Up must be provided for 230\/400 voltage inputs and 1.5 kV Up must be provided for the protection of electrical-electronic equipment.<\/span><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The selection of the low voltage surge arresters we use in lightning and overvoltage protection is of great importance in correct protection. The wrong product selection unfortunately results in the breakdown of sensitive devices in many facilities. In order to choose the right product, let&#8217;s first look at the types of surge arresters. AG Surge [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":6962,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[137],"tags":[],"class_list":["post-7596","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-protection"],"_links":{"self":[{"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/posts\/7596","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/comments?post=7596"}],"version-history":[{"count":0,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/posts\/7596\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/media\/6962"}],"wp:attachment":[{"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/media?parent=7596"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/categories?post=7596"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/tags?post=7596"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}