{"id":7535,"date":"2021-10-02T13:23:31","date_gmt":"2021-10-02T13:23:31","guid":{"rendered":"https:\/\/sayprotest.com\/motor-korumada-sik-yapilan-hatalar\/"},"modified":"2021-10-12T20:17:38","modified_gmt":"2021-10-12T20:17:38","slug":"common-mistakes-in-engine-protection","status":"publish","type":"post","link":"https:\/\/www.saypro.com.tr\/en\/common-mistakes-in-engine-protection\/","title":{"rendered":"Common Mistakes in Motor Protection"},"content":{"rendered":"<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"4\">Electric motors make up about seventy percent of the electrical energy used in industry.<\/span> <span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"1\" data-number-of-phrases=\"4\">For this reason, the correct protection of electric motors and the prevention of unplanned stops provide an increase in efficiency spread throughout the plant.<\/span> <span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"2\" data-number-of-phrases=\"4\">Although there are no clear-cut rules in engine protection, there are basic elements to consider in engine protection.<\/span> <span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"3\" data-number-of-phrases=\"4\">In this article, we will take a look at the common mistakes made while protecting the engine.<\/span><\/span><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-7028 \" src=\"http:\/\/sayprotest.com\/wp-content\/uploads\/2021\/10\/motor-1024x680.jpeg\" alt=\"\" width=\"738\" height=\"490\" srcset=\"https:\/\/www.saypro.com.tr\/wp-content\/uploads\/2021\/10\/motor-1024x680.jpeg 1024w, https:\/\/www.saypro.com.tr\/wp-content\/uploads\/2021\/10\/motor-300x199.jpeg 300w, https:\/\/www.saypro.com.tr\/wp-content\/uploads\/2021\/10\/motor-768x510.jpeg 768w, https:\/\/www.saypro.com.tr\/wp-content\/uploads\/2021\/10\/motor-1536x1020.jpeg 1536w, https:\/\/www.saypro.com.tr\/wp-content\/uploads\/2021\/10\/motor-720x478.jpeg 720w, https:\/\/www.saypro.com.tr\/wp-content\/uploads\/2021\/10\/motor.jpeg 1600w\" sizes=\"(max-width: 738px) 100vw, 738px\" \/><\/p>\n<p><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"8\">Incorrect Selection of Low Voltage Protection Values<\/span><\/span><\/strong><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"2\" data-number-of-phrases=\"8\">Motors operating below their rated voltage may be subject to overheating and have a shorter lifespan.<\/span> <span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"3\" data-number-of-phrases=\"8\">According to the National Electrical Manufacturers Association (NEMA), it is not recommended to run motors below 90% of their rated voltage for extended periods of time.<\/span> <span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"4\" data-number-of-phrases=\"8\">Note that if an undervoltage protection is set too high, it may disconnect the motor when not needed.<\/span> <\/span><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"6\" data-number-of-phrases=\"8\">For example, a three-phase motor with a rated voltage of 230V has 207V of the lowest acceptable operating voltage according to NEMA.<\/span> <span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"7\" data-number-of-phrases=\"8\">However, if an adjustable Low Voltage relay is set to 220V, a voltage drop of 5% will be sufficient to disconnect the motor.<\/span><\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-7064 size-full\" src=\"http:\/\/sayprotest.com\/wp-content\/uploads\/2021\/10\/ls.png\" alt=\"\" width=\"595\" height=\"434\" srcset=\"https:\/\/www.saypro.com.tr\/wp-content\/uploads\/2021\/10\/ls.png 595w, https:\/\/www.saypro.com.tr\/wp-content\/uploads\/2021\/10\/ls-300x219.png 300w\" sizes=\"(max-width: 595px) 100vw, 595px\" \/><\/p>\n<p><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">Thermal Overload Setting<\/span><\/span><\/strong><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">The basic requirement for overload protection setting for motors is 125% of full load currents according to NEC; however, it is also necessary to consider the overload relay instructions. If the 125% value is not integrated into the relay, you should set it to +25% current on the motor nameplate.<\/span><\/span><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">If the overload protection is set too low, the motor may be disconnected even during normal operation. This means unnecessary downtime and the engine is not protected at the desired level. Of course, the overload protection should not be set too high either, as the motor will not be adequately protected against overload. For example, if you add 15% when setting an overload relay with a built-in value of 125%, the actual overload protection value will be 144% and this does not meet the desired standards. <\/span><\/span><\/p>\n<p><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">Magnetic Protection Set<\/span><\/span><\/strong><\/p>\n<div class=\"J0lOec\"><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"tr\" data-phrase-index=\"0\" data-number-of-phrases=\"1\">In situations such as fault conditions, the magnetic protections must disconnect the motor immediately, but allow inrush current without disconnection. The point that should not be forgotten here is that if the magnetic protection is fixed, the trip curve and the inrush current values \u200b\u200bshould be allowed to operate in a coordinated manner. It is helpful to make sure that the inrush current is lower, especially if the motor has a low voltage starter, soft starter or variable frequency drive.<\/span><\/span><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Electric motors make up about seventy percent of the electrical energy used in industry. For this reason, the correct protection of electric motors and the prevention of unplanned stops provide an increase in efficiency spread throughout the plant. Although there are no clear-cut rules in engine protection, there are basic elements to consider in engine [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":7063,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[137],"tags":[],"class_list":["post-7535","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-protection"],"_links":{"self":[{"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/posts\/7535","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/comments?post=7535"}],"version-history":[{"count":0,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/posts\/7535\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/media\/7063"}],"wp:attachment":[{"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/media?parent=7535"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/categories?post=7535"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.saypro.com.tr\/en\/wp-json\/wp\/v2\/tags?post=7535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}